Operators track a 100-ft-diameter tank by gallons per foot of level. How many gallons does each foot of depth hold?
About this practice test
20 exam-style questions for the Arizona water distribution operator exam, across every topic on the test. Pick an answer, check it, read why.
Original practice questions written for Mainsora — not real exam items.
See all 20 questions with answers and explanations
Operators track a 100-ft-diameter tank by gallons per foot of level. How many gallons does each foot of depth hold?
- 7,850 gal
- 14,680 gal
- 58,718 gal
- 65,469 gal
Answer: 58,718 gal
Why: One foot of depth in a 7,850-ft² tank is 7,850 ft³, or about 58,700 gal.
- Area = 0.785 × 100² = 7,850 ft²
- 7,850 ft² × 1 ft × 7.48 = 58,718 gal per ft
A zone's HGL is 1,180 ft. Policy requires at least 40 psi static at every service. What is the highest service elevation the zone can serve?
- 1,272.4 ft
- 1,162.7 ft
- 1,140.0 ft
- 1,087.6 ft
Answer: 1,087.6 ft
Why: A service must sit at least 92.4 ft below the HGL to see 40 psi.
- 40 psi × 2.31 = 92.4 ft of pressure head needed
- 1,180 − 92.4 = 1,087.6 ft
A 24-inch transmission main carries 6.0 MGD. What is the average velocity?
- 0.74 ft/s
- 2.96 ft/s
- 5.91 ft/s
- 22.12 ft/s
Answer: 2.96 ft/s
Why: 6 MGD is 9.28 cfs; dividing by the 3.14-ft² area gives about 2.96 ft/s.
- Q = 6.0 × 1.547 = 9.28 cfs.
- A = 0.785 × 2² = 3.14 ft².
- V = 9.28 ÷ 3.14 = 2.96 ft/s.
Free chlorine reacting with natural organic matter mainly produces which regulated byproducts?
- Bromate and chlorite
- TTHMs and HAA5
- Nitrite and nitrate
- Lead and copper
Answer: TTHMs and HAA5
Why: Chlorine reacts with organic material to form TTHMs and HAA5, which are regulated disinfection byproducts.
A hypochlorination system delivers the equivalent of 40 lb/day of available chlorine at a dose of 2.5 mg/L. What flow, in MGD, is being treated?
Answer: 1.92 MGD
Why: Rearranging the pounds formula gives flow = 40 / (2.5 x 8.34) = 1.92 MGD.
- Flow (MGD) = lb/day / (mg/L x 8.34)
- Flow = 40 / (2.5 x 8.34) = 1.92 MGD
Ten 1-lb tablets of 65% available chlorine are placed in a new 10-inch main 7,500 ft long. What chlorine dose results?
- 16.6 mg/L
- 25.5 mg/L
- 39.2 mg/L
- 190.6 mg/L
Answer: 25.5 mg/L
Why: Volume = 0.785 x (10/12)^2 x 7,500 x 7.48 = 30,594 gal = 0.0306 MG. Available chlorine = 10 x 0.65 = 6.5 lb. Dose = 6.5 / (8.34 x 0.0306) = 25.5 mg/L.
- Vol = 0.785 x 0.8333^2 x 7,500 x 7.48 = 30,594 gal = 0.030594 MG
- Dose = (10 x 0.65) / (8.34 x 0.030594) = 25.5 mg/L
A dry-barrel hydrant still holds water an hour after use, even with a cap removed. Flushing the drains with the hydrant open two to three turns did not help. What should be done until it is repaired?
- Pump the barrel out after each use
- Plug the drain and fill the barrel with antifreeze
- Paint the bonnet red to show it is out of service
- Leave it full; the barrel is rated for freezing
Answer: Pump the barrel out after each use
Why: If a hydrant still does not drain after attempting to flush the drains, it should be pumped out after each use so water does not freeze in the barrel.
- A hydrant that will not drain will freeze in cold weather.
- Pump the barrel after every use until the drain is fixed.
A sewage lift station needs potable water for pump seals. What is the accepted way to provide it?
- Direct connection with a single check valve
- Direct connection with a hose bibb vacuum breaker
- Direct connection with a pressure vacuum breaker
- Air gap to a tank, with a pump feeding the seals
Answer: Air gap to a tank, with a pump feeding the seals
Why: A direct seal-water line to a sewage pump is a serious cross-connection; accepted practice is an air gap to a tank, with a separate pump supplying the seals.
A pump makes a crackling, gravel-like noise and its suction gauge shows high vacuum. What is happening?
- Air release from an open vent
- Packing that is too loose
- Water hammer caused by the discharge check valve slamming
- Cavitation from inlet pressure below vapor pressure
Answer: Cavitation from inlet pressure below vapor pressure
Why: Cavitation occurs when absolute pressure at the pump inlet falls below vapor pressure. Vapor cavities form and collapse violently, damaging the impeller.
- High suction vacuum + noise = signs of cavitation.
- Vapor cavities form at low pressure and collapse violently at the impeller.
For a pump and motor in normal operation, which ranking of horsepower values is correct?
- Motor hp > brake hp > water hp
- Water hp > brake hp > motor hp
- Brake hp > motor hp > water hp
- Motor hp > water hp > brake hp
Answer: Motor hp > brake hp > water hp
Why: Power goes in at the motor, some is lost there, more is lost in the pump, and what remains reaches the water.
A routine sample is E. coli-positive. One repeat is total coliform-positive but E. coli-negative; the others are negative. What is the compliance status?
- E. coli MCL violation
- No violation, because the repeat had no E. coli
- Level 1 trigger only
- Monitoring violation
Answer: E. coli MCL violation
Why: Any total coliform-positive repeat following an E. coli-positive routine sample is an E. coli MCL violation (141.860(a)(2)).
A 6-ft-deep trench runs 120 ft along a street. A ladder, ramp, or stairway must be placed so that no worker has to travel more than how far laterally to reach it?
- 10 ft
- 25 ft
- 50 ft
- 100 ft
Answer: 25 ft
Why: 29 CFR 1926.651(c)(2): trenches 4 ft or more deep need a means of egress requiring no more than 25 ft of lateral travel.
Under federal rules, how long must a public water system keep records of its microbiological (coliform) analyses?
- At least 3 years
- At least 10 years
- At least 5 years
- At least 12 years
Answer: At least 5 years
Why: 40 CFR 141.33(a): records of microbiological and turbidity analyses are kept for not less than 5 years.
A rectangular storage basin is 40 ft long and 20 ft wide, with water 12 ft deep. How many gallons does it hold?
- 80,064 gal
- 71,808 gal
- 9,600 gal
- 1,283 gal
Answer: 71,808 gal
Why: Rectangle volume L × W × H in ft³, then × 7.48 gal/ft³.
- V = 40 × 20 × 12 = 9,600 ft³
- 9,600 × 7.48 = 71,808 gal
A pressure zone has a hydraulic grade line at 1,020 ft. What is the static pressure at a house at elevation 850 ft?
- 441.7 psi
- 392.7 psi
- 368.1 psi
- 73.6 psi
Answer: 73.6 psi
Why: Pressure = (HGL − elevation) × 0.433 = 73.6 psi.
- Head = 1,020 − 850 = 170 ft
- 170 × 0.433 = 73.6 psi
A 10-inch main is carrying 600 gpm. What is the average velocity in the main?
- 18.34 ft/s
- 2.45 ft/s
- 0.73 ft/s
- 0.61 ft/s
Answer: 2.45 ft/s
Why: Velocity equals flow in cfs divided by area in ft²; 600 gpm is 1.34 cfs and the 10-in area is 0.545 ft².
- Q = 600 gpm ÷ 7.48 ÷ 60 = 1.337 cfs.
- A = 0.785 × (0.833 ft)² = 0.545 ft².
- V = Q ÷ A = 1.337 ÷ 0.545 = 2.45 ft/s.
Routine samples show 0.6 mg/L free chlorine at nearby looped mains but only a trace at a hydrant on a long dead-end main serving three homes. What is the most appropriate first operational response?
- Flush the dead end now and on a routine schedule
- Raise the plant chlorine dose until the dead end reads 0.6 mg/L
- Close the valve feeding the dead end until demand increases
- Switch the sample site to a looped main with better residual
Answer: Flush the dead end now and on a routine schedule
Why: Stagnant water in dead ends loses residual; flushing replaces it with fresh water, and routine flushing (or looping) keeps water age down.
A small system treats 0.8 MGD with 65% calcium hypochlorite at a dose of 2.5 mg/L. How many pounds of calcium hypochlorite are needed per day?
- 3.1 lb/day
- 10.8 lb/day
- 16.7 lb/day
- 25.7 lb/day
Answer: 25.7 lb/day
Why: Compute pure chlorine (16.7 lb/day), then divide by 0.65 to get pounds of product.
- Chlorine = 0.8 x 2.5 x 8.34 = 16.7 lb/day
- Product = 16.7 / 0.65 = 25.7 lb/day
A crew must cut out a section of asbestos-cement main. Which practice is prohibited by OSHA's construction asbestos standard?
- Keeping the pipe surface wet throughout the cutting work
- An abrasive disc saw with no point-of-cut ventilation
- Collecting all chips and dust with a HEPA-filtered vacuum
- Bagging the cut pieces and debris in leak-tight containers
Answer: An abrasive disc saw with no point-of-cut ventilation
Why: OSHA prohibits high-speed abrasive disc saws not equipped with point-of-cut ventilation; wet methods, HEPA vacuums and leak-tight waste containers are required work practices.
When setting a new traffic-model dry-barrel hydrant, about where should the break (breakaway) flange end up relative to finished grade?
- Flush with the ground
- About 12 inches above the ground
- About 6 inches below the ground
- About 2 inches above the ground
Answer: About 2 inches above the ground
Why: The break flange should be about 2 inches above the ground, so a vehicle strike breaks the hydrant at the flange rather than below grade.
Arizona exam at a glance
- Passing score
- 70%
Ready for the full exam experience?
The full course adds every lesson as a hands-on illustration, all practice questions with worked solutions and two timed 100-question practice exams. One-time payment from $29.
Common questions
How many questions are on the Arizona water distribution exam?
Arizona does not publish the question count on an official page we could verify; check the current candidate handbook from Arizona Department of Environmental Quality (ADEQ), Operator Certification Program.
Is this practice test free?
Yes — 20 questions with instant explanations, no sign-up. Math questions show every step.
Can I use a formula sheet on the exam?
ABC/WPI exams come with a formula/conversion table, and many state-written exams provide one too; check your state's candidate information. Our explanations use the same standard constants (7.48 gal/ft³, 8.34 lb/gal, 2.31 ft/psi, 0.785 D²).
How should I use a practice test?
Answer before peeking, read every explanation (even when you're right), and go back to the lesson for any topic you miss. Take a full timed 100-question practice exam a week before test day.