Question 1 of 20Math: area, volume and conversions

A tank holds 45,000 gal. What is that volume in cubic feet?

Pick an answer and check it.

About this practice test

20 exam-style questions for the Wisconsin water distribution operator exam (State-run), across every topic on the test. Pick an answer, check it, read why.

Original practice questions written for Mainsora — not real exam items.

See all 20 questions with answers and explanations
  1. A tank holds 45,000 gal. What is that volume in cubic feet?

    • 1,667 ft³
    • 5,396 ft³
    • 6,016 ft³
    • 336,600 ft³

    Answer: 6,016 ft³

    Why: Each cubic foot holds 7.48 gal, so divide gallons by 7.48.

  2. One psi of water pressure corresponds to how many feet of water (head)?

    • 0.433 ft
    • 2.31 ft
    • 14.7 ft
    • 33.9 ft

    Answer: 2.31 ft

    Why: A column of water 2.31 ft tall exerts 1 psi at its base.

  3. A new subdivision will have 320 homes averaging 2.8 people each. At 110 gpcd, what average flow in gpm will it add to the system?

    • 24.4 gpm
    • 68.4 gpm
    • 1,642.7 gpm
    • 4,106.7 gpm

    Answer: 68.4 gpm

    Why: Population times per-capita use gives 98,560 gpd, which is 68.4 gpm on average.

    1. Population = 320 × 2.8 = 896 people.
    2. Demand = 896 × 110 = 98,560 gpd.
    3. 98,560 ÷ 1,440 = 68.4 gpm.
  4. The pH of a system's water rises from 7.0 to 8.5 while the free chlorine residual stays the same. What happens to disinfection effectiveness?

    • It improves because more HOCl is formed
    • It is unchanged because free chlorine is constant
    • It improves because chloramines begin to form
    • It drops because more of the chlorine is OCl-

    Answer: It drops because more of the chlorine is OCl-

    Why: As pH rises, HOCl dissociates into the weaker OCl- ion, so the same free residual disinfects less effectively.

  5. Crews will disinfect 2,000 ft of 6-inch main at 25 mg/L using 12.5% sodium hypochlorite (assume 8.34 lb/gal). About how many gallons of hypochlorite are needed?

    • 0.073 gal
    • 0.59 gal
    • 2.3 gal
    • 4.9 gal

    Answer: 0.59 gal

    Why: The main holds about 2,936 gal; that needs 0.61 lb of chlorine, which is about 0.59 gal of 12.5% hypochlorite.

    1. Volume = 0.785 x 0.5^2 x 2,000 x 7.48 = 2,936 gal
    2. Chlorine = 0.002936 MG x 25 x 8.34 = 0.61 lb
    3. Gallons = 0.61 / (8.34 x 0.125) = 0.59 gal
  6. A crew must connect a new PVC main to an existing cast iron main of a different outside diameter. What should they use?

    • A manufacturer-approved transition coupling
    • A standard PVC push-on bell fitting
    • A flanged adapter buried without any restraint
    • A lead-caulked bell joint packed with jute

    Answer: A manufacturer-approved transition coupling

    Why: Manufacturer-approved transition joints are required between dissimilar piping materials.

  7. An upper-zone fill line draws so much water during peak hours that pressures upstream of it, in the lower zone, fall below 35 psi. Which valve on the fill line would keep the upstream pressure from dropping below a set value?

    • Pressure relief valve
    • Swing check valve
    • Pressure reducing valve (PRV)
    • Pressure sustaining valve

    Answer: Pressure sustaining valve

    Why: Pressure sustaining valves maintain pressure, closing down as needed so upstream pressure does not fall below the setting. A PRV controls the downstream side instead.

    1. The goal is to protect the pressure UPSTREAM of the valve.
    2. That is the job of a pressure sustaining valve, which throttles to hold its inlet pressure.
  8. A funeral home with embalming equipment is served by a 1-inch line. What containment assembly should the utility require at the service?

    • Double check valve assembly
    • Reduced-pressure assembly
    • Residential dual check
    • Hose bibb vacuum breaker

    Answer: Reduced-pressure assembly

    Why: Funeral parlors and similar sites are high health hazards that need RP protection (or an air gap).

  9. A pressure gauge at ground level at the base of an elevated tank reads 60 psi. The bottom of the tank bowl is 100 ft above the gauge. What is the water depth in the bowl?

    • 16.7 ft
    • 26.0 ft
    • 38.6 ft
    • 138.6 ft

    Answer: 38.6 ft

    Why: Convert the gauge reading to feet of head (× 2.31), then subtract the height of the bowl floor above the gauge.

    1. Total head = 60 psi × 2.31 ft/psi = 138.6 ft above the gauge
    2. Depth in bowl = 138.6 − 100 = 38.6 ft
  10. A 40-hp motor runs fully loaded 14 hours a day. How many kilowatt-hours does it use per day?

    • 30 kWh
    • 418 kWh
    • 560 kWh
    • 751 kWh

    Answer: 418 kWh

    Why: Energy is power in kW times hours of operation.

    1. kW = 40 × 0.746 = 29.8 kW.
    2. kWh = 29.8 × 14 hr = 418 kWh.
  11. A system collects 10 lead tap samples (Tier 3-5 sites, no Tier 1 or 2). Results in µg/L: 2, 3, 3, 4, 5, 6, 8, 9, 12, 16. What is the 90th percentile lead level?

    • 6.8 µg/L
    • 9 µg/L
    • 16 µg/L
    • 12 µg/L

    Answer: 12 µg/L

    Why: Rank results low to high and multiply the sample count by 0.9: 10 x 0.9 = 9, so the 9th-ranked result (12 µg/L) is the 90th percentile.

    1. Sort ascending: 2, 3, 3, 4, 5, 6, 8, 9, 12, 16.
    2. 10 x 0.9 = 9 -> 9th value = 12 µg/L.
  12. An excavation 10 ft deep in Type A soil will be open for several days. What is the maximum allowable slope under OSHA Subpart P, Appendix B?

    • 1/2:1 (63°)
    • 1:1 (45°)
    • 1-1/2:1 (34°)
    • 3/4:1 (53°)

    Answer: 3/4:1 (53°)

    Why: Table B-1 sets Type A at 3/4 horizontal to 1 vertical (53°) for excavations 20 ft or less.

  13. Minimum night flow into a district metered area has crept up a little each night for a week while billed use is unchanged. What is the most likely explanation?

    • A newly developing leak inside the area
    • A customer meter starting to under-register
    • Morning peak demand starting earlier
    • A stuck altitude valve at an outside tank

    Answer: A newly developing leak inside the area

    Why: PA DEP: if night flows into a DMA rise slowly over several days, a new leak is likely emerging, and leak detection should be assigned to that area.

  14. A tank level transmitter reads 2.75 ft above the outlet. How many inches is that?

    Answer: 33 in

    Why: Feet × 12 = inches.

  15. A tank water level is at elevation 560 ft. What is the static pressure at a service connection at elevation 412 ft, in psi? (Round to one decimal.)

    Answer: 64.1 psi

    Why: Static psi = height of water above the point × 0.433.

    1. Head = 560 − 412 = 148 ft
    2. 148 × 0.433 = 64.1 psi
  16. A utility produces 96 MG per 30-day month, and 14% of production is non-revenue water. To meet a 10% goal at the same production, by about how much must non-revenue water be cut, in gallons per day?

    • 128,000 gpd
    • 320,000 gpd
    • 448,000 gpd
    • 3,840,000 gpd

    Answer: 128,000 gpd

    Why: Cutting from 14% to 10% removes 4% of 96 MG per month, about 128,000 gpd.

    1. Reduction = 14% − 10% = 4% of production.
    2. 0.04 × 96,000,000 = 3,840,000 gal/month.
    3. ÷ 30 = 128,000 gpd.
  17. A DPD test shows a total chlorine residual of 1.8 mg/L and a free chlorine residual of 1.2 mg/L. What is the combined chlorine residual?

    • 3.0 mg/L
    • 1.5 mg/L
    • 1.2 mg/L
    • 0.6 mg/L

    Answer: 0.6 mg/L

    Why: Total chlorine is free plus combined, so combined = 1.8 - 1.2 = 0.6 mg/L.

  18. A hypochlorination system delivers the equivalent of 40 lb/day of available chlorine at a dose of 2.5 mg/L. What flow, in MGD, is being treated?

    Answer: 1.92 MGD

    Why: Rearranging the pounds formula gives flow = 40 / (2.5 x 8.34) = 1.92 MGD.

    1. Flow (MGD) = lb/day / (mg/L x 8.34)
    2. Flow = 40 / (2.5 x 8.34) = 1.92 MGD
  19. Why should dead-end mains be minimized?

    • They raise available fire flow at the end
    • Water stagnates and loses residual
    • They increase the C-factor of the main
    • They prevent water hammer when valves close

    Answer: Water stagnates and loses residual

    Why: Dead ends promote water quality degradation and low or no chlorine residual; looping keeps water moving.

  20. A homeowner reports a broken pipe in the basement and is not home. To shut off that one house without entering it or affecting neighbors, the operator should close the:

    • Gate valve on the main in front of the house
    • Curb stop, reached through the curb box
    • Corporation stop, by excavating at the main
    • Nearest fire hydrant auxiliary valve

    Answer: Curb stop, reached through the curb box

    Why: The curb stop is the service shutoff near the property line. It is operated through the curb box, so one customer is isolated without digging or a main shutdown.

    1. The curb stop is the utility shutoff near the property line.
    2. It is reached with a key through the curb box.

Wisconsin exam at a glance

Exam
State-run
Questions
40

Read the full Wisconsin guide →

Ready for the full exam experience?

The full course adds every lesson as a hands-on illustration, all practice questions with worked solutions and two timed 100-question practice exams. One-time payment from $29.

Common questions

How many questions are on the Wisconsin water distribution exam?

The Wisconsin distribution exam has 40 questions (State-run).

Is this practice test free?

Yes — 20 questions with instant explanations, no sign-up. Math questions show every step.

Can I use a formula sheet on the exam?

ABC/WPI exams come with a formula/conversion table, and many state-written exams provide one too; check your state's candidate information. Our explanations use the same standard constants (7.48 gal/ft³, 8.34 lb/gal, 2.31 ft/psi, 0.785 D²).

How should I use a practice test?

Answer before peeking, read every explanation (even when you're right), and go back to the lesson for any topic you miss. Take a full timed 100-question practice exam a week before test day.