Idaho Water Distribution Practice Test

20 free exam-style questions for the Idaho exam. Instant explanations, no sign-up.

Question 1 of 20Math: area, volume and conversions

A trench 200 ft long and 2.5 ft wide is dug to a depth of 54 inches. How many cubic yards are removed?

Pick an answer and check it.

About this practice test

20 exam-style questions for the Idaho water distribution operator exam (PSI), across every topic on the test. Pick an answer, check it, read why.

Original practice questions written for Mainsora — not real exam items.

See all 20 questions with answers and explanations
  1. A trench 200 ft long and 2.5 ft wide is dug to a depth of 54 inches. How many cubic yards are removed?

    • 2,250.0 yd³
    • 1,000.0 yd³
    • 250.0 yd³
    • 83.3 yd³

    Answer: 83.3 yd³

    Why: Convert 54 in to 4.5 ft, then 2,250 ft³ ÷ 27 = 83.3 yd³.

    1. Depth = 54 ÷ 12 = 4.5 ft; V = 200 × 2.5 × 4.5 = 2,250 ft³
    2. 2,250 ÷ 27 = 83.3 yd³
  2. Under static conditions, hydrant A at elevation 640 ft reads 72 psi. Hydrant B on the same main is at elevation 710 ft. What should hydrant B read?

    • 102.3 psi
    • 72.0 psi
    • 41.7 psi
    • 2.0 psi

    Answer: 41.7 psi

    Why: Going uphill 70 ft costs 30.3 psi, so B reads about 41.7 psi.

    1. Rise = 710 − 640 = 70 ft; 70 × 0.433 = 30.3 psi
    2. 72 − 30.3 = 41.7 psi
  3. Water flows at 1.8 ft/s in a 12-inch main that reduces to an 8-inch main. With the same flow, what is the velocity in the 8-inch section?

    • 0.80 ft/s
    • 1.20 ft/s
    • 2.70 ft/s
    • 4.05 ft/s

    Answer: 4.05 ft/s

    Why: Area changes with diameter squared; the 8-in pipe has 1/2.25 the area, so velocity is 2.25 times higher.

    1. Q is constant, so V₂ = V₁ × (D₁ ÷ D₂)².
    2. V₂ = 1.8 × (12 ÷ 8)² = 1.8 × 2.25 = 4.05 ft/s.
  4. In chloramination, about what chlorine-to-ammonia-nitrogen weight ratio nearly eliminates free ammonia in the treated water?

    • 1:1
    • 1:5
    • 10:1
    • 5:1

    Answer: 5:1

    Why: A ratio of about 5:1 chlorine to ammonia-N by weight forms mostly monochloramine and leaves little free ammonia to feed nitrifying bacteria.

  5. A hypochlorination system delivers the equivalent of 40 lb/day of available chlorine at a dose of 2.5 mg/L. What flow, in MGD, is being treated?

    Answer: 1.92 MGD

    Why: Rearranging the pounds formula gives flow = 40 / (2.5 x 8.34) = 1.92 MGD.

    1. Flow (MGD) = lb/day / (mg/L x 8.34)
    2. Flow = 40 / (2.5 x 8.34) = 1.92 MGD
  6. A main break is reported. Before any digging, which step must be completed?

    • Call 811 so other utilities can be marked
    • Collect bacteriological samples at the site
    • Pour a new thrust block at the nearest bend
    • Disinfect the repair clamp with a 1% solution

    Answer: Call 811 so other utilities can be marked

    Why: Main break response includes locating the leak and notifying the one-call (811) system before excavation.

  7. When opening a hydrant, where should the operator stand?

    • Downhill from the hydrant in the flow path
    • Directly over the auxiliary valve box
    • Directly in front of the pumper nozzle
    • On the side of the hydrant that has no cap

    Answer: On the side of the hydrant that has no cap

    Why: Caps or the barrel are under pressure and may become dislodged, so the operator stands on the side of the hydrant without a cap.

    1. Caps and the barrel are under pressure and can blow off.
    2. Stand on the side without a cap.
  8. For a cross-connection to actually contaminate a public water system, which three conditions must occur together?

    • A main break, a fire flow, and a positive coliform
    • No protection, a physical link, and backflow
    • A customer complaint, a low residual, and a pressure drop
    • A dead end, high water age, and warm temperatures

    Answer: No protection, a physical link, and backflow

    Why: Contamination requires unprotected (or poorly protected) piping, a physical connection to a contaminant source, and backflow conditions at the same time.

  9. An elevated tank bowl can be treated as a cylinder 50 ft in diameter. The water depth is 20 ft. How many gallons are stored?

    • 39,250 gal
    • 73,398 gal
    • 293,590 gal
    • 327,345 gal

    Answer: 293,590 gal

    Why: Use 0.785 × D² × depth for cubic feet, then multiply by 7.48 gal/ft³.

    1. Volume = 0.785 × 50² × 20 = 39,250 ft³
    2. 39,250 ft³ × 7.48 gal/ft³ = 293,590 gal
  10. A pump delivers 1,500 gpm at 175 ft TDH. Pump efficiency is 80% and motor efficiency is 92%. It runs 20 hours a day and power costs $0.11 per kWh. What is the daily energy cost in dollars?

    Answer: 147.82 $

    Why: Find motor horsepower from flow, head and both efficiencies, convert to kW, multiply by hours and rate.

    1. mhp = 1,500 × 175 ÷ (3,960 × 0.80 × 0.92) = 90.1 hp.
    2. kW = 90.1 × 0.746 = 67.2 kW; kWh = 67.2 × 20 = 1,344 kWh.
    3. Cost = 1,343.8 kWh × $0.11 = $147.82.
  11. Which term describes a NONENFORCEABLE health goal set at a level where no known adverse health effect would occur, with a margin of safety?

    • Maximum contaminant level goal (MCLG)
    • Action level (AL)
    • Maximum residual disinfectant level (MRDL)
    • Maximum contaminant level (MCL)

    Answer: Maximum contaminant level goal (MCLG)

    Why: An MCLG is a nonenforceable health goal; the enforceable MCL is set as close to the MCLG as feasible.

  12. Fusible plugs on chlorine cylinders and ton containers are designed to melt at about what temperature?

    • 158–165°F
    • 100–110°F
    • 212–220°F
    • 300–320°F

    Answer: 158–165°F

    Why: PA DEP and Chlorine Institute guidance give a fusible plug melting range of 158 to 165°F (70 to 74°C) to relieve pressure before a container ruptures.

  13. Minimum night flow into a district metered area has crept up a little each night for a week while billed use is unchanged. What is the most likely explanation?

    • A newly developing leak inside the area
    • A customer meter starting to under-register
    • Morning peak demand starting earlier
    • A stuck altitude valve at an outside tank

    Answer: A newly developing leak inside the area

    Why: PA DEP: if night flows into a DMA rise slowly over several days, a new leak is likely emerging, and leak detection should be assigned to that area.

  14. What is the volume, in cubic feet, of 300 ft of 24-inch transmission main?

    • 236 ft³
    • 942 ft³
    • 7,046 ft³
    • 135,648 ft³

    Answer: 942 ft³

    Why: 0.785 × 4 ft² × 300 ft = 942 ft³; no gallon conversion is needed.

    1. D = 24 in = 2 ft
    2. V = 0.785 × 2² × 300 = 942 ft³
  15. A reservoir has 32 ft of water above its outlet. What is the pressure at the outlet, in psi? (Round to one decimal.)

    Answer: 13.9 psi

    Why: psi = feet × 0.433.

  16. A booster station is pumping 900 gpm. What is this flow in cfs?

    • 120.32 cfs
    • 15.00 cfs
    • 2.01 cfs
    • 1.30 cfs

    Answer: 2.01 cfs

    Why: Divide gpm by 7.48 to get ft³/min, then by 60 to get ft³/s: about 2.01 cfs.

    1. 900 gpm ÷ 7.48 = 120.3 ft³/min.
    2. 120.3 ÷ 60 = 2.01 cfs.
  17. A system's monthly average chlorine residuals for the last four quarters average 3.1 mg/L, but one August sample read 4.6 mg/L. Regarding the chlorine MRDL of 4.0 mg/L, what is the status?

    • In violation, because one sample exceeded 4.0 mg/L
    • In violation, because the August monthly average must be below 4.0
    • In compliance only if a repeat sample is below 2.0 mg/L
    • In compliance, because compliance is a running annual average

    Answer: In compliance, because compliance is a running annual average

    Why: The chlorine and chloramine MRDL (4.0 mg/L as Cl2) is judged on a running annual average, computed quarterly, of monthly averages.

  18. A system treats 2.0 MGD with chlorine gas at a dose of 1.5 mg/L. How many pounds of chlorine are fed per day?

    • 0.36 lb/day
    • 3.0 lb/day
    • 12.5 lb/day
    • 25 lb/day

    Answer: 25 lb/day

    Why: Gas chlorine is 100% available, so lb/day = 2.0 x 1.5 x 8.34 = 25 lb/day.

    1. lb/day = MGD x mg/L x 8.34
    2. lb/day = 2.0 x 1.5 x 8.34 = 25 lb/day
  19. An Iowa specification (SUDAS Section 5030) tests new mains at 1.5 times the working pressure or 150 psi, whichever is greater. A main will operate at 110 psi. What is the test pressure?

    • 110 psi
    • 150 psi
    • 165 psi
    • 260 psi

    Answer: 165 psi

    Why: 1.5 x 110 = 165 psi, which is greater than 150 psi, so 165 psi governs.

    1. 1.5 x 110 psi = 165 psi
    2. 165 > 150, so test at 165 psi
  20. A new neighborhood sits in a valley 150 ft below the rest of a pressure zone, and static pressures there would exceed pipe and plumbing limits. What device is normally installed on the main feeding the neighborhood?

    • Pressure reducing valve
    • Air/vacuum valve
    • Pressure sustaining valve
    • Check valve

    Answer: Pressure reducing valve

    Why: Pressure reducing valves create head loss to break pressure so downstream pressures stay below pipe ratings. They often form the boundary of a lower pressure zone.

    1. 150 ft of extra elevation is about 65 psi more pressure.
    2. A PRV creates head loss to keep downstream pressure below a set point.

Idaho exam at a glance

Exam
PSI

Read the full Idaho guide →

Ready for the full exam experience?

The full course adds every lesson as a hands-on illustration, all practice questions with worked solutions and two timed 100-question practice exams. One-time payment from $29.

Common questions

How many questions are on the Idaho water distribution exam?

Idaho does not publish the question count on an official page we could verify; check the current candidate handbook from Idaho Board of Drinking Water and Wastewater Professionals, Division of Occupational and Professional Licenses (DOPL).

Is this practice test free?

Yes — 20 questions with instant explanations, no sign-up. Math questions show every step.

Can I use a formula sheet on the exam?

ABC/WPI exams come with a formula/conversion table, and many state-written exams provide one too; check your state's candidate information. Our explanations use the same standard constants (7.48 gal/ft³, 8.34 lb/gal, 2.31 ft/psi, 0.785 D²).

How should I use a practice test?

Answer before peeking, read every explanation (even when you're right), and go back to the lesson for any topic you miss. Take a full timed 100-question practice exam a week before test day.