Spoil from a trench 250 ft long, 3 ft wide and 5 ft deep will be hauled in trucks that carry 10 yd³ each. How many full or partial truckloads are needed? (Whole number.)
About this practice test
20 exam-style questions for the Washington water distribution operator exam (ABC (Water Professionals International)), across every topic on the test. Pick an answer, check it, read why.
Original practice questions written for Mainsora — not real exam items.
See all 20 questions with answers and explanations
Spoil from a trench 250 ft long, 3 ft wide and 5 ft deep will be hauled in trucks that carry 10 yd³ each. How many full or partial truckloads are needed? (Whole number.)
Answer: 14 loads
Why: 138.9 yd³ needs 14 loads; a partial load still requires a trip. (Ignores soil swell.)
- V = 250 × 3 × 5 = 3,750 ft³ ÷ 27 = 138.9 yd³
- 138.9 ÷ 10 = 13.9 → 14 loads
A pressure zone has a hydraulic grade line at 1,020 ft. What is the static pressure at a house at elevation 850 ft?
- 441.7 psi
- 392.7 psi
- 368.1 psi
- 73.6 psi
Answer: 73.6 psi
Why: Pressure = (HGL − elevation) × 0.433 = 73.6 psi.
- Head = 1,020 − 850 = 170 ft
- 170 × 0.433 = 73.6 psi
Water flows at 1.8 ft/s in a 12-inch main that reduces to an 8-inch main. With the same flow, what is the velocity in the 8-inch section?
- 0.80 ft/s
- 1.20 ft/s
- 2.70 ft/s
- 4.05 ft/s
Answer: 4.05 ft/s
Why: Area changes with diameter squared; the 8-in pipe has 1/2.25 the area, so velocity is 2.25 times higher.
- Q is constant, so V₂ = V₁ × (D₁ ÷ D₂)².
- V₂ = 1.8 × (12 ÷ 8)² = 1.8 × 2.25 = 4.05 ft/s.
A crew will disinfect a large standpipe by spraying the interior with chlorine solution. What strength and contact time are required on all surfaces?
- At least 50 mg/L, held for at least 6 hours
- At least 200 mg/L for at least 30 minutes
- At least 25 mg/L for at least 24 hours
- At least 10 mg/L for at least 24 hours
Answer: At least 200 mg/L for at least 30 minutes
Why: The spray method applies at least 200 mg/L solution to all surfaces up to the overflow and keeps it in contact at least 30 minutes.
A contractor installs 1,000 ft of 8-inch main and will disinfect it at 25 mg/L. How many pounds of chlorine (100%) are required?
- 0.073 lb
- 0.14 lb
- 0.54 lb
- 78 lb
Answer: 0.54 lb
Why: The main holds about 2,611 gallons; at 25 mg/L that requires 0.54 lb of chlorine.
- Diameter = 8/12 = 0.667 ft; volume = 0.785 x 0.667^2 x 1,000 x 7.48 = 2,611 gal
- Volume = 0.002611 MG
- lb = 0.002611 x 25 x 8.34 = 0.54 lb
An Iowa specification (SUDAS Section 5030) tests new mains at 1.5 times the working pressure or 150 psi, whichever is greater. A main will operate at 110 psi. What is the test pressure?
- 110 psi
- 150 psi
- 165 psi
- 260 psi
Answer: 165 psi
Why: 1.5 x 110 = 165 psi, which is greater than 150 psi, so 165 psi governs.
- 1.5 x 110 psi = 165 psi
- 165 > 150, so test at 165 psi
A small apartment complex has a 3-inch turbine meter. Daytime peaks are high, but at night usage is only a few gpm, and the account bills less than expected. What is the most likely cause?
- The turbine meter cannot accurately register low flows
- The building has too little pressure
- The meter is over-registering during the high daytime peaks
- Turbine meters only register flow in one direction
Answer: The turbine meter cannot accurately register low flows
Why: Velocity meters such as turbines do not accurately measure low flow rates, so low night flows go under-registered. Sites like this usually need a compound meter.
- Velocity (turbine) meters do not register low flows accurately.
- A site with wide-ranging flows usually needs a compound meter.
Before testing an RP at an office building, the tester asks the owner for permission to shut the water off and to tell occupants not to use water. Why the occupant warning?
- Water use will damage the test kit gauges
- Occupant use would invalidate the test readings
- The relief valve will flood the building if water is used
- Opening a tap could siphon from unprotected outlets
Answer: Opening a tap could siphon from unprotected outlets
Why: With the supply off, any water use drops pressure to zero and can siphon from unprotected cross-connections inside the building.
A tank overflow pipe is connected directly to a storm drain inlet. What correction does EPA Region 8 guidance call for?
- Provide an air gap of at least 3 pipe diameters above the drain
- Add a second overflow pipe of the same size
- Plug the overflow and rely on the altitude valve to prevent overfill
- Install a gate valve on the overflow and keep it closed
Answer: Provide an air gap of at least 3 pipe diameters above the drain
Why: Overflows cannot be directly connected to a sewer or storm drain. An air gap of at least 3 pipe diameters prevents backflow and stops the tank from inhaling drain air.
- A direct connection is a cross-connection to the storm drain.
- Break it with an air gap of at least 3 pipe diameters.
A worn pump's efficiency drops from 80% to 70% while it delivers the same flow at the same head. The brake horsepower it requires:
- Increases about 10%
- Increases about 14%
- Decreases about 12.5%
- Stays the same
Answer: Increases about 14%
Why: bhp = whp ÷ efficiency, so falling from 80% to 70% raises bhp by 0.80/0.70 = 1.14.
- bhp ∝ 1 ÷ efficiency.
- 0.80 ÷ 0.70 = 1.143, an increase of about 14%.
A customer complains of red-brown water after a main flushing. The most likely cause is:
- Dissolved air
- Manganese
- Iron
- Copper
Answer: Iron
Why: Iron causes rusty color and red-orange staining.
A crew lowers a steel trench box into a trench to protect pipe layers working inside it. Under OSHA definitions, the trench box is which kind of protective system?
- A shoring system
- A shield system
- A benching system
- A sloping system
Answer: A shield system
Why: 1926.650 defines a shield as a structure able to withstand cave-in forces and protect employees inside it; shields are often called trench boxes.
A main break flowed an estimated 350 gpm for 2.5 hours before it was isolated. How many gallons were lost?
- 875 gal
- 21,000 gal
- 52,500 gal
- 1,260,000 gal
Answer: 52,500 gal
Why: 350 gpm × 2.5 h × 60 min/h = 52,500 gal.
- 2.5 h × 60 min/h = 150 min.
- 350 gpm × 150 min = 52,500 gal.
A small clearwell holds 2,500 ft³ of water. How many gallons is that?
Answer: 18,700 gal
Why: Multiply cubic feet by 7.48 to get gallons.
On a static pressure survey of one zone, hydrant X reads 20 psi more than hydrant Y. How much lower is hydrant X than hydrant Y?
- 0.0 ft
- 8.7 ft
- 20.0 ft
- 46.2 ft
Answer: 46.2 ft
Why: In one static zone, pressure differences come only from elevation: 20 psi ≈ 46.2 ft.
A 2.0-MG elevated tank averages 65% full. The volume that flows out (and is replaced) each day averages 0.40 MG. Estimate the average detention time (water age) in the tank.
- 0.31 days
- 3.25 days
- 5.00 days
- 7.69 days
Answer: 3.25 days
Why: Detention time is stored volume divided by the flow through it: 1.30 MG ÷ 0.40 MGD = 3.25 days.
- Average stored volume = 2.0 MG × 0.65 = 1.30 MG.
- Detention time = 1.30 MG ÷ 0.40 MG/day = 3.25 days.
In a free-chlorine system, quarterly data show TTHM rising steadily toward the far end, but HAA5 is lower at the most remote site (residual about 0.1 mg/L) than at mid-system sites. What best explains the HAA5 pattern?
- HAA5 converts into TTHM as the water ages further
- HAA5 volatilizes into air in elevated storage tanks
- Bacteria biodegrade HAA5 where residual is low
- Lab interference from low chlorine in the remote sample
Answer: Bacteria biodegrade HAA5 where residual is low
Why: HAA5 can be biodegraded by bacteria once the residual is nearly gone, so HAA5 may fall at the oldest water while TTHM keeps rising.
A standpipe 30 ft in diameter is full to 60 ft. It will be disinfected at 25 mg/L with 12.5% sodium hypochlorite (assume 8.34 lb/gal). How many gallons of hypochlorite are required?
Answer: 63.4 gal
Why: Find volume, chlorine pounds, then divide by the 1.04 lb of available chlorine per gallon of 12.5% product.
- Volume = 0.785 x 30^2 x 60 x 7.48 = 317,077 gal = 0.317 MG
- Chlorine = 0.317 x 25 x 8.34 = 66.1 lb
- Gallons = 66.1 / (8.34 x 0.125) = 63.4 gal
Which AWWA standard is followed when disinfecting new or repaired water mains?
- AWWA C651
- AWWA C652
- AWWA C900
- AWWA C600
Answer: AWWA C651
Why: AWWA C651 covers disinfection of water mains; Ten States and many state rules require it for new, cleaned and repaired mains.
When tapping a horizontal main for a new service, at what position is the corporation stop typically installed?
- 12 o'clock, on top of the main
- 6 o'clock, on the bottom of the main
- 3 o'clock or 9 o'clock
- 10 o'clock or 2 o'clock
Answer: 10 o'clock or 2 o'clock
Why: The PA DEP manual gives 10 or 2 o'clock as the typical tap positions: off the crown of the main and well above its bottom.
Washington exam at a glance
- Exam
- ABC (Water Professionals International)
- Questions
- 100
- Time
- 180 min
- Formula sheet
- PSI provides the WPI formula/conversion sheet, pencils and scratch paper
Ready for the full exam experience?
The full course adds every lesson as a hands-on illustration, all practice questions with worked solutions and two timed 100-question practice exams. One-time payment from $29.
Common questions
How many questions are on the Washington water distribution exam?
The Washington distribution exam has 100 questions with 180 minutes allowed (ABC (Water Professionals International)).
Is this practice test free?
Yes — 20 questions with instant explanations, no sign-up. Math questions show every step.
Can I use a formula sheet on the exam?
ABC/WPI exams come with a formula/conversion table, and many state-written exams provide one too; check your state's candidate information. Our explanations use the same standard constants (7.48 gal/ft³, 8.34 lb/gal, 2.31 ft/psi, 0.785 D²).
How should I use a practice test?
Answer before peeking, read every explanation (even when you're right), and go back to the lesson for any topic you miss. Take a full timed 100-question practice exam a week before test day.