How many feet of 6-inch pipe hold 1,000 gal of water? (Round to the nearest foot.)
About this practice test
20 exam-style questions for the Oregon water distribution operator exam (ABC), across every topic on the test. Pick an answer, check it, read why.
Original practice questions written for Mainsora — not real exam items.
See all 20 questions with answers and explanations
How many feet of 6-inch pipe hold 1,000 gal of water? (Round to the nearest foot.)
Answer: 681 ft
Why: Length = volume (ft³) ÷ cross-sectional area (ft²) ≈ 681 ft.
- 1,000 gal ÷ 7.48 = 133.7 ft³
- 133.7 ÷ (0.785 × 0.5²) = 133.7 ÷ 0.196 = 681 ft
A tank water level is at elevation 560 ft. What is the static pressure at a service connection at elevation 412 ft, in psi? (Round to one decimal.)
Answer: 64.1 psi
Why: Static psi = height of water above the point × 0.433.
- Head = 560 − 412 = 148 ft
- 148 × 0.433 = 64.1 psi
A 16-inch main must be flushed at 5 ft/s. Each available hydrant can discharge about 1,000 gpm. What is the minimum number of hydrants that must be opened?
- 13 hydrants
- 4 hydrants
- 3 hydrants
- 2 hydrants
Answer: 4 hydrants
Why: The main needs about 3,132 gpm; three 1,000-gpm hydrants fall short, so four are required.
- A = 0.785 × (1.333 ft)² = 1.396 ft².
- Q = 1.396 × 5 × 7.48 × 60 = 3,132 gpm.
- 3,132 ÷ 1,000 = 3.13, so round up to 4 hydrants.
Why do TTHM results at the same distribution sites usually peak in late summer?
- Faster reactions and higher chlorine demand
- Summer demand shortens water age throughout the system
- Source water bromide is removed by summer algae growth
- Chlorine is less reactive with organics in warm water
Answer: Faster reactions and higher chlorine demand
Why: Reactions go faster and further at higher temperature, and higher chlorine demand often means a higher dose, so DBP formation potential rises.
A system treats 2.0 MGD with chlorine gas at a dose of 1.5 mg/L. How many pounds of chlorine are fed per day?
- 0.36 lb/day
- 3.0 lb/day
- 12.5 lb/day
- 25 lb/day
Answer: 25 lb/day
Why: Gas chlorine is 100% available, so lb/day = 2.0 x 1.5 x 8.34 = 25 lb/day.
- lb/day = MGD x mg/L x 8.34
- lb/day = 2.0 x 1.5 x 8.34 = 25 lb/day
Under Ten States Standards, what is the minimum horizontal separation between a new water main and a parallel gravity sanitary sewer?
- 18 inches, center to center
- 10 feet, edge to edge
- 5 feet, edge to edge
- 3 feet, center to center
Answer: 10 feet, edge to edge
Why: Water mains are laid at least 10 feet horizontally from gravity sewers, measured edge to edge.
An operator finds water discharging from an elevated tank overflow every night when demand is low, although SCADA shows the booster pumps are off. Which component should be checked first?
- The air release valve on the tank riser pipe
- The cathodic protection system
- The tank vent screen
- The altitude valve on the tank inlet
Answer: The altitude valve on the tank inlet
Why: Repeated overflow with gravity filling means the level control is not closing. The altitude valve is designed to close at the high level and prevent overflow.
- With pumps off, the tank is filling from system pressure.
- The valve that should stop filling at the high level is the altitude valve.
Which installation meets the rules for an atmospheric vacuum breaker (AVB)?
- Installed before a solenoid valve, 6 inches above the highest outlet
- Installed after the last valve, 6 inches above the highest outlet
- Installed after the last valve, 6 inches below the highest outlet
- Installed on a boiler feed line with a downstream shutoff
Answer: Installed after the last valve, 6 inches above the highest outlet
Why: AVBs go downstream of the last valve, at least 6 inches above the flood rim or highest outlet, with no shutoff after them and no backpressure.
A centrifugal pump sits above the reservoir it draws from and has been off for two days. Before starting it, the operator must make sure that:
- The packing is fully tightened
- The motor leads are reversed
- The discharge valve is fully closed and locked
- The pump casing is full of water (primed)
Answer: The pump casing is full of water (primed)
Why: The casing must be full of water before starting. A pump above its source can drain while stopped, so it must be primed first.
- With suction lift, the casing can drain while the pump is stopped.
- It must be refilled (primed) before starting.
A pump delivers 2,400 gpm at 230 ft TDH with a wire-to-water efficiency of 70%. Power costs $0.10 per kWh. What is the energy cost to pump one million gallons?
- $103.16
- $72.21
- $138.29
- $50.55
Answer: $103.16
Why: Electrical kW times the hours needed to pump 1 MG gives kWh; at $0.10/kWh that is about $103.
- Input hp = 2,400 × 230 ÷ (3,960 × 0.70) = 199.1 hp = 148.5 kW.
- Time for 1 MG = 1,000,000 ÷ 2,400 = 416.7 min = 6.94 hr.
- kWh = 148.5 × 6.94 = 1,032; cost = $103.16.
What is the MRDL for chlorine dioxide?
- 1.0 mg/L as ClO2
- 4.0 mg/L as ClO2
- 0.08 mg/L as ClO2
- 0.8 mg/L as ClO2
Answer: 0.8 mg/L as ClO2
Why: Chlorine dioxide's MRDL is 0.8 mg/L as ClO2.
Under OSHA's permit-required confined space standard, oxygen is acceptable for entry only within which range?
- 19.5% to 23.5%
- 16% to 21%
- 18% to 22%
- 20.9% to 25%
Answer: 19.5% to 23.5%
Why: 1910.146 defines a hazardous atmosphere as one with oxygen below 19.5% or above 23.5%.
Minimum night flow into a district metered area has crept up a little each night for a week while billed use is unchanged. What is the most likely explanation?
- A newly developing leak inside the area
- A customer meter starting to under-register
- Morning peak demand starting earlier
- A stuck altitude valve at an outside tank
Answer: A newly developing leak inside the area
Why: PA DEP: if night flows into a DMA rise slowly over several days, a new leak is likely emerging, and leak detection should be assigned to that area.
How many gallons of water are in 500 ft of 8-inch main?
- 174 gal
- 326 gal
- 1,305 gal
- 1,455 gal
Answer: 1,305 gal
Why: Pipe volume is a cylinder: 0.785 × D² × L gives ft³, then × 7.48 converts to gallons.
- V = 0.785 × (0.667 ft)² × 500 ft = 174.4 ft³
- 174.4 ft³ × 7.48 gal/ft³ = 1,305 gal
A tank water surface is at elevation 950 ft. A pressure gauge on the main below is at elevation 835 ft. With no flow, what should the gauge read?
- 411.4 psi
- 361.6 psi
- 265.7 psi
- 49.8 psi
Answer: 49.8 psi
Why: Static pressure depends on the vertical distance between water surface and gauge: 115 ft × 0.433 ≈ 49.8 psi.
- Head = 950 − 835 = 115 ft
- 115 × 0.433 = 49.8 psi
A 2.0-MG elevated tank averages 65% full. The volume that flows out (and is replaced) each day averages 0.40 MG. Estimate the average detention time (water age) in the tank.
- 0.31 days
- 3.25 days
- 5.00 days
- 7.69 days
Answer: 3.25 days
Why: Detention time is stored volume divided by the flow through it: 1.30 MG ÷ 0.40 MGD = 3.25 days.
- Average stored volume = 2.0 MG × 0.65 = 1.30 MG.
- Detention time = 1.30 MG ÷ 0.40 MG/day = 3.25 days.
A tank has been recoated, cleaned and disinfected. What must happen before it is returned to service?
- The tank must sit empty for 72 hours to cure
- The chlorine residual must drop to zero
- Bacteriological tests must be negative
- Customers must be notified to boil water
Answer: Bacteriological tests must be negative
Why: After disinfection, bacteriological samples are taken; the tank goes back in service only if results are negative, otherwise disinfection is repeated.
Plant flow is 3.5 MGD. The chlorine demand is 2.3 mg/L and a free residual of 0.5 mg/L is required. At what lb/day setting should the gas chlorinator rotameter be set?
- 9.8 lb/day
- 15 lb/day
- 67 lb/day
- 82 lb/day
Answer: 82 lb/day
Why: The rotameter setting must deliver demand plus residual: 3.5 x 2.8 x 8.34 = 82 lb/day.
- Dose = 2.3 + 0.5 = 2.8 mg/L
- Setting = 3.5 x 2.8 x 8.34 = 82 lb/day
A main break is reported. Before any digging, which step must be completed?
- Call 811 so other utilities can be marked
- Collect bacteriological samples at the site
- Pour a new thrust block at the nearest bend
- Disinfect the repair clamp with a 1% solution
Answer: Call 811 so other utilities can be marked
Why: Main break response includes locating the leak and notifying the one-call (811) system before excavation.
Bench testing shows a customer meter registers only 95% of the water passing through it. Over a billing year it recorded 380,000 gallons. About how much water passed through without being registered?
- 19,000 gal
- 20,000 gal
- 361,000 gal
- 400,000 gal
Answer: 20,000 gal
Why: The recorded volume is 95% of the actual volume, so actual = 380,000 ÷ 0.95 = 400,000 gal and 20,000 gal went unregistered. In a water audit that is an apparent loss.
- Actual = recorded ÷ accuracy = 380,000 ÷ 0.95 = 400,000 gal
- Unregistered = 400,000 − 380,000 = 20,000 gal
Oregon exam at a glance
- Exam
- ABC
- Questions
- 100
- Passing score
- 70%
- Formula sheet
- ABC formula/conversion table for water treatment, distribution and lab exams (WPI says its standardized exams are given with this table)
Ready for the full exam experience?
The full course adds every lesson as a hands-on illustration, all practice questions with worked solutions and two timed 100-question practice exams. One-time payment from $29.
Common questions
How many questions are on the Oregon water distribution exam?
The Oregon distribution exam has 100 questions (ABC).
Is this practice test free?
Yes — 20 questions with instant explanations, no sign-up. Math questions show every step.
Can I use a formula sheet on the exam?
ABC/WPI exams come with a formula/conversion table, and many state-written exams provide one too; check your state's candidate information. Our explanations use the same standard constants (7.48 gal/ft³, 8.34 lb/gal, 2.31 ft/psi, 0.785 D²).
How should I use a practice test?
Answer before peeking, read every explanation (even when you're right), and go back to the lesson for any topic you miss. Take a full timed 100-question practice exam a week before test day.