Question 1 of 20Math: area, volume and conversions

A crew must know how much water is in 1,000 ft of 6-inch main. How many gallons does it hold? (Round to the nearest gallon.)

Pick an answer and check it.

About this practice test

20 exam-style questions for the District of Columbia water distribution operator exam, across every topic on the test. Pick an answer, check it, read why.

Original practice questions written for Mainsora — not real exam items.

See all 20 questions with answers and explanations
  1. A crew must know how much water is in 1,000 ft of 6-inch main. How many gallons does it hold? (Round to the nearest gallon.)

    Answer: 1,468 gal

    Why: 0.785 × 0.25 ft² × 1,000 ft × 7.48 gal/ft³ ≈ 1,468 gal.

    1. D = 6 in = 0.5 ft; V = 0.785 × 0.5² × 1,000 = 196.25 ft³
    2. 196.25 × 7.48 = 1,468 gal
  2. Under static conditions, hydrant A at elevation 640 ft reads 72 psi. Hydrant B on the same main is at elevation 710 ft. What should hydrant B read?

    • 102.3 psi
    • 72.0 psi
    • 41.7 psi
    • 2.0 psi

    Answer: 41.7 psi

    Why: Going uphill 70 ft costs 30.3 psi, so B reads about 41.7 psi.

    1. Rise = 710 − 640 = 70 ft; 70 × 0.433 = 30.3 psi
    2. 72 − 30.3 = 41.7 psi
  3. A 24-inch transmission main carries 6.0 MGD. What is the average velocity?

    • 0.74 ft/s
    • 2.96 ft/s
    • 5.91 ft/s
    • 22.12 ft/s

    Answer: 2.96 ft/s

    Why: 6 MGD is 9.28 cfs; dividing by the 3.14-ft² area gives about 2.96 ft/s.

    1. Q = 6.0 × 1.547 = 9.28 cfs.
    2. A = 0.785 × 2² = 3.14 ft².
    3. V = 9.28 ÷ 3.14 = 2.96 ft/s.
  4. Routine samples show 0.6 mg/L free chlorine at nearby looped mains but only a trace at a hydrant on a long dead-end main serving three homes. What is the most appropriate first operational response?

    • Flush the dead end now and on a routine schedule
    • Raise the plant chlorine dose until the dead end reads 0.6 mg/L
    • Close the valve feeding the dead end until demand increases
    • Switch the sample site to a looped main with better residual

    Answer: Flush the dead end now and on a routine schedule

    Why: Stagnant water in dead ends loses residual; flushing replaces it with fresh water, and routine flushing (or looping) keeps water age down.

  5. A small system treats 0.8 MGD with 65% calcium hypochlorite at a dose of 2.5 mg/L. How many pounds of calcium hypochlorite are needed per day?

    • 3.1 lb/day
    • 10.8 lb/day
    • 16.7 lb/day
    • 25.7 lb/day

    Answer: 25.7 lb/day

    Why: Compute pure chlorine (16.7 lb/day), then divide by 0.65 to get pounds of product.

    1. Chlorine = 0.8 x 2.5 x 8.34 = 16.7 lb/day
    2. Product = 16.7 / 0.65 = 25.7 lb/day
  6. At a tee where the surrounding soil was recently disturbed by another utility, which approach is most appropriate?

    • Add mechanical joint restraint at the fitting
    • Skip restraint because soft soil absorbs the thrust
    • Pour a thrust block against the disturbed soil anyway
    • Increase the depth of bedding under the tee only

    Answer: Add mechanical joint restraint at the fitting

    Why: Mechanical restraint devices are useful as an addition or alternative to thrust blocking where soil is disturbed or cannot be compacted.

  7. When setting a new traffic-model dry-barrel hydrant, about where should the break (breakaway) flange end up relative to finished grade?

    • Flush with the ground
    • About 12 inches above the ground
    • About 6 inches below the ground
    • About 2 inches above the ground

    Answer: About 2 inches above the ground

    Why: The break flange should be about 2 inches above the ground, so a vehicle strike breaks the hydrant at the flange rather than below grade.

  8. Which situation is an example of backpressure?

    • A garden hose left in a bucket during a main shutdown
    • A sink spray nozzle lying in a full sink during low pressure
    • A boiler whose pressure exceeds city pressure
    • Heavy use on lower floors pulling water from upper floors

    Answer: A boiler whose pressure exceeds city pressure

    Why: Backpressure is backflow driven by downstream pressure (pump, boiler, elevated piping) greater than supply pressure.

  9. A 500,000-gallon tank exchanges 150,000 gallons per day through its fill and draw cycle. What is its daily turnover?

    • 15%
    • 30%
    • 70%
    • 333%

    Answer: 30%

    Why: Daily turnover is the volume exchanged per day divided by tank volume: 150,000 ÷ 500,000 = 30% per day.

    1. Turnover = water exchanged ÷ tank volume × 100
    2. 150,000 ÷ 500,000 × 100 = 30%
  10. A pump test shows 31.5 water horsepower while the shaft receives 42 brake horsepower. What is the pump efficiency?

    • 11%
    • 25%
    • 75%
    • 133%

    Answer: 75%

    Why: Pump efficiency is output (water hp) divided by input (brake hp).

    1. Efficiency = whp ÷ bhp × 100.
    2. 31.5 ÷ 42 × 100 = 75%.
  11. A Tier 3 public notice must be provided no later than:

    • 90 days
    • 30 days
    • 6 months
    • 1 year

    Answer: 1 year

    Why: Tier 3 notice is due within one year and repeated annually while the situation persists.

  12. After a heavy overnight rainstorm, a crew returns to an open, shored trench. Before anyone enters, who must inspect the excavation and protective system?

    • A competent person
    • A registered professional engineer
    • The certified operator in charge
    • A local building inspector

    Answer: A competent person

    Why: 1926.651(k) requires a competent person to inspect daily, before work starts, and after every rainstorm or other event that increases hazards.

  13. A pressure gauge on a fire hydrant reads 52 psi. What is the equivalent pressure head?

    • 22.5 ft
    • 52.0 ft
    • 120.1 ft
    • 1,201 ft

    Answer: 120.1 ft

    Why: Head (ft) = psi × 2.31 = 52 × 2.31 = 120.1 ft.

    1. 1 psi = 2.31 ft of water.
    2. 52 psi × 2.31 = 120.1 ft.
  14. A tank level transmitter reads 2.75 ft above the outlet. How many inches is that?

    Answer: 33 in

    Why: Feet × 12 = inches.

  15. A pressure recorder shows 115.5 ft of head. What is that in psi?

    • 4.2 psi
    • 50.0 psi
    • 115.5 psi
    • 266.8 psi

    Answer: 50.0 psi

    Why: psi = feet × 0.433 (or feet ÷ 2.31) = 50 psi.

  16. With the supply pumps off, the level in a 50-ft-diameter standpipe falls 2.4 ft in one hour. What was the average demand during that hour?

    • 79 gpm
    • 587 gpm
    • 2,349 gpm
    • 35,231 gpm

    Answer: 587 gpm

    Why: The slice drawn down holds 35,231 gal; over 60 minutes that is about 587 gpm.

    1. V = 0.785 × 50² × 2.4 = 4,710 ft³ × 7.48 = 35,231 gal.
    2. 35,231 gal ÷ 60 min = 587 gpm.
  17. Residual drops from 1.2 to 0.3 mg/L along a 2-mile run of old unlined cast-iron main, though travel time is only a few hours. What is the most likely cause?

    • Wall demand from corrosion and biofilm
    • Chlorine escaping through air-release valves
    • Excess flushing velocity in the main
    • Dilution by water from a parallel main

    Answer: Wall demand from corrosion and biofilm

    Why: Exposed iron and wall growths consume chlorine, so residual can fall quickly even when water age is short.

  18. A 250,000-gallon ground storage tank will be disinfected by filling it with water dosed at 50 mg/L. How many pounds of chlorine (100%) are needed?

    • 12.5 lb
    • 104 lb
    • 160 lb
    • 1,043 lb

    Answer: 104 lb

    Why: Pounds = MG x mg/L x 8.34 = 0.25 x 50 x 8.34 = 104 lb of chlorine.

    1. Volume = 250,000 gal = 0.25 MG
    2. lb = 0.25 x 50 x 8.34 = 104 lb
  19. Ten 1-lb tablets of 65% available chlorine are placed in a new 10-inch main 7,500 ft long. What chlorine dose results?

    • 16.6 mg/L
    • 25.5 mg/L
    • 39.2 mg/L
    • 190.6 mg/L

    Answer: 25.5 mg/L

    Why: Volume = 0.785 x (10/12)^2 x 7,500 x 7.48 = 30,594 gal = 0.0306 MG. Available chlorine = 10 x 0.65 = 6.5 lb. Dose = 6.5 / (8.34 x 0.0306) = 25.5 mg/L.

    1. Vol = 0.785 x 0.8333^2 x 7,500 x 7.48 = 30,594 gal = 0.030594 MG
    2. Dose = (10 x 0.65) / (8.34 x 0.030594) = 25.5 mg/L
  20. A homeowner reports a broken pipe in the basement and is not home. To shut off that one house without entering it or affecting neighbors, the operator should close the:

    • Gate valve on the main in front of the house
    • Curb stop, reached through the curb box
    • Corporation stop, by excavating at the main
    • Nearest fire hydrant auxiliary valve

    Answer: Curb stop, reached through the curb box

    Why: The curb stop is the service shutoff near the property line. It is operated through the curb box, so one customer is isolated without digging or a main shutdown.

    1. The curb stop is the utility shutoff near the property line.
    2. It is reached with a key through the curb box.

District of Columbia exam at a glance

Read the full District of Columbia guide →

Ready for the full exam experience?

The full course adds every lesson as a hands-on illustration, all practice questions with worked solutions and two timed 100-question practice exams. One-time payment from $29.

Common questions

How many questions are on the District of Columbia water distribution exam?

District of Columbia does not publish the question count on an official page we could verify; check the current candidate handbook from U.S. EPA Region 3 (administers the drinking water program in DC; DC does not have primacy).

Is this practice test free?

Yes — 20 questions with instant explanations, no sign-up. Math questions show every step.

Can I use a formula sheet on the exam?

ABC/WPI exams come with a formula/conversion table, and many state-written exams provide one too; check your state's candidate information. Our explanations use the same standard constants (7.48 gal/ft³, 8.34 lb/gal, 2.31 ft/psi, 0.785 D²).

How should I use a practice test?

Answer before peeking, read every explanation (even when you're right), and go back to the lesson for any topic you miss. Take a full timed 100-question practice exam a week before test day.