Texas Water Distribution Practice Test
20 free exam-style questions for the Texas exam. Instant explanations, no sign-up.
A trench 200 ft long and 2.5 ft wide is dug to a depth of 54 inches. How many cubic yards are removed?
About this practice test
20 exam-style questions for the Texas water distribution operator exam (State-run (TCEQ exams)), across every topic on the test. Pick an answer, check it, read why.
Original practice questions written for Mainsora — not real exam items.
See all 20 questions with answers and explanations
A trench 200 ft long and 2.5 ft wide is dug to a depth of 54 inches. How many cubic yards are removed?
- 2,250.0 yd³
- 1,000.0 yd³
- 250.0 yd³
- 83.3 yd³
Answer: 83.3 yd³
Why: Convert 54 in to 4.5 ft, then 2,250 ft³ ÷ 27 = 83.3 yd³.
- Depth = 54 ÷ 12 = 4.5 ft; V = 200 × 2.5 × 4.5 = 2,250 ft³
- 2,250 ÷ 27 = 83.3 yd³
A reservoir has 32 ft of water above its outlet. What is the pressure at the outlet, in psi? (Round to one decimal.)
Answer: 13.9 psi
Why: psi = feet × 0.433.
A new 12-inch main is to be flushed at 5 ft/s. What flow must be discharged?
- 29 gpm
- 236 gpm
- 1,762 gpm
- 7,046 gpm
Answer: 1,762 gpm
Why: A 12-in main has 0.785 ft² of area; at 5 ft/s that is 3.93 cfs, or about 1,762 gpm.
- A = 0.785 × (1 ft)² = 0.785 ft².
- Q = 0.785 × 5 = 3.925 cfs.
- 3.925 × 7.48 × 60 = 1,762 gpm.
Free chlorine reacting with natural organic matter mainly produces which regulated byproducts?
- Bromate and chlorite
- TTHMs and HAA5
- Nitrite and nitrate
- Lead and copper
Answer: TTHMs and HAA5
Why: Chlorine reacts with organic material to form TTHMs and HAA5, which are regulated disinfection byproducts.
The chlorine dose is 2.1 mg/L and the chlorine demand of the water is 0.9 mg/L. What residual should remain?
- 3.0 mg/L
- 1.9 mg/L
- 1.2 mg/L
- 0.43 mg/L
Answer: 1.2 mg/L
Why: Whatever chlorine is not consumed by the demand remains as residual: 2.1 - 0.9 = 1.2 mg/L.
- Residual = Dose - Demand
- Residual = 2.1 - 0.9 = 1.2 mg/L
A 12-inch main is capped (dead end) and will be tested at 150 psi. What is the thrust on the cap?
- 113 lb
- 1,800 lb
- 16,956 lb
- 67,824 lb
Answer: 16,956 lb
Why: Thrust on a plug equals pressure times the cross-sectional area: 0.785 x 12^2 in^2 x 150 psi = 16,956 lb.
- Area = 0.785 x 12 x 12 = 113.04 in^2
- Thrust = 113.04 x 150 = 16,956 lb
In a two-hydrant fire flow test, which readings are taken at the test (residual) hydrant?
- Static and residual pressure
- Pitot pressure only
- Static pressure and pitot pressure
- Residual pressure and flow in gpm
Answer: Static and residual pressure
Why: Static and residual pressures are read with a gauge on the test hydrant. The pitot reading is taken in the stream at the flow hydrant.
- Test hydrant: cap gauge for static, then residual while the other hydrant flows.
- Flow hydrant: pitot reading.
An irrigation system's PVB is at the front of a lot, but sprinkler heads on a slope behind the house sit 15 feet higher. Why is this a problem?
- The uphill water column backpressures the PVB
- The PVB will lose pressure and stop all irrigation flow
- The PVB air inlet will freeze in the uphill pipe
- Uphill heads create a submerged inlet in the PVB
Answer: The uphill water column backpressures the PVB
Why: Elevated downstream piping exerts head back on the device (about 0.433 psi per foot); PVBs are not rated for backpressure, so an RP or relocation is needed.
A high-lift station has had two main breaks shortly after power failures tripped all pumps at once. Which measure most directly addresses the cause?
- Install surge tanks and surge relief valves
- Add a second check valve on each pump discharge
- Install a larger altitude valve at the tank
- Raise the pump discharge pressure setting
Answer: Install surge tanks and surge relief valves
Why: Pumps stopping suddenly cause surges that can burst or collapse pipe. Surge tanks, pressure and surge relief valves, and vacuum relief valves are the listed control measures.
- Sudden pump stoppage creates transients (water hammer).
- Surge control devices reduce those pressure spikes and vacuums.
A pump test shows 31.5 water horsepower while the shaft receives 42 brake horsepower. What is the pump efficiency?
- 11%
- 25%
- 75%
- 133%
Answer: 75%
Why: Pump efficiency is output (water hp) divided by input (brake hp).
- Efficiency = whp ÷ bhp × 100.
- 31.5 ÷ 42 × 100 = 75%.
Which treatment is evaluated in corrosion control studies to reduce lead and copper leaching?
- Fluoride addition
- Breakpoint chlorination
- Potassium permanganate feed for oxidation
- Orthophosphate inhibitor addition
Answer: Orthophosphate inhibitor addition
Why: Corrosion control studies evaluate alkalinity/pH adjustment and orthophosphate- or silicate-based inhibitors.
Testing in a 5-ft excavation near a decaying organic fill shows 18.9% oxygen. What does OSHA's excavation standard require before the crew works in it?
- No action, since 18.9% is near normal
- A half-face cartridge respirator
- Entry limited to 15 minutes per worker
- Ventilation or respiratory protection
Answer: Ventilation or respiratory protection
Why: 1926.651(g)(1)(ii): where the atmosphere contains less than 19.5% oxygen, adequate precautions such as ventilation or respiratory protection must be taken.
A system corrected a violation, and its last corrective action was completed in March 2025. Under 40 CFR 141.33, records of those actions must be kept until at least when?
- March 2026
- March 2030
- March 2035
- March 2028
Answer: March 2028
Why: 141.33(b): records of action taken to correct violations are kept at least 3 years after the last action for that violation.
A tank level transmitter reads 2.75 ft above the outlet. How many inches is that?
Answer: 33 in
Why: Feet × 12 = inches.
A PRV at elevation 500 ft is set to deliver 45 psi downstream. A customer downstream of the PRV is at elevation 450 ft. With no flow, what is the customer's static pressure?
- 261.5 psi
- 66.7 psi
- 45.0 psi
- 23.4 psi
Answer: 66.7 psi
Why: The PRV fixes the downstream HGL; a customer 50 ft lower gains about 21.7 psi over the setting.
- Downstream HGL = 500 + 45 × 2.31 = 603.95 ft
- Customer pressure = (603.95 − 450) × 0.433 = 66.7 psi
With the supply pumps off, the level in a 50-ft-diameter standpipe falls 2.4 ft in one hour. What was the average demand during that hour?
- 79 gpm
- 587 gpm
- 2,349 gpm
- 35,231 gpm
Answer: 587 gpm
Why: The slice drawn down holds 35,231 gal; over 60 minutes that is about 587 gpm.
- V = 0.785 × 50² × 2.4 = 4,710 ft³ × 7.48 = 35,231 gal.
- 35,231 gal ÷ 60 min = 587 gpm.
Residual drops from 1.2 to 0.3 mg/L along a 2-mile run of old unlined cast-iron main, though travel time is only a few hours. What is the most likely cause?
- Wall demand from corrosion and biofilm
- Chlorine escaping through air-release valves
- Excess flushing velocity in the main
- Dilution by water from a parallel main
Answer: Wall demand from corrosion and biofilm
Why: Exposed iron and wall growths consume chlorine, so residual can fall quickly even when water age is short.
A 150-lb cylinder on a scale read 112 lb on Monday morning and 81 lb the following Monday morning. The well pumped an average of 0.35 MGD over that week. What was the average chlorine dose?
- 0.66 mg/L
- 1.5 mg/L
- 10.6 mg/L
- 12.7 mg/L
Answer: 1.5 mg/L
Why: Weight loss gives 31 lb in a week, 4.43 lb/day; dividing by 0.35 x 8.34 gives 1.5 mg/L.
- Chlorine used = 112 - 81 = 31 lb over 7 days = 4.43 lb/day
- Dose = 4.43 / (0.35 x 8.34) = 1.5 mg/L
A crew must connect a new PVC main to an existing cast iron main of a different outside diameter. What should they use?
- A manufacturer-approved transition coupling
- A standard PVC push-on bell fitting
- A flanged adapter buried without any restraint
- A lead-caulked bell joint packed with jute
Answer: A manufacturer-approved transition coupling
Why: Manufacturer-approved transition joints are required between dissimilar piping materials.
When opening a hydrant, where should the operator stand?
- Downhill from the hydrant in the flow path
- Directly over the auxiliary valve box
- Directly in front of the pumper nozzle
- On the side of the hydrant that has no cap
Answer: On the side of the hydrant that has no cap
Why: Caps or the barrel are under pressure and may become dislodged, so the operator stands on the side of the hydrant without a cap.
- Caps and the barrel are under pressure and can blow off.
- Stand on the side without a cap.
Texas exam at a glance
- Exam
- State-run (TCEQ exams)
- Time
- 180 min
- Passing score
- 70%
Ready for the full exam experience?
The full course adds every lesson as a hands-on illustration, all practice questions with worked solutions and two timed 100-question practice exams. One-time payment from $29.
Common questions
How many questions are on the Texas water distribution exam?
Texas does not publish the question count on an official page we could verify; check the current candidate handbook from Texas Commission on Environmental Quality (TCEQ) — Occupational Licensing.
Is this practice test free?
Yes — 20 questions with instant explanations, no sign-up. Math questions show every step.
Can I use a formula sheet on the exam?
ABC/WPI exams come with a formula/conversion table, and many state-written exams provide one too; check your state's candidate information. Our explanations use the same standard constants (7.48 gal/ft³, 8.34 lb/gal, 2.31 ft/psi, 0.785 D²).
How should I use a practice test?
Answer before peeking, read every explanation (even when you're right), and go back to the lesson for any topic you miss. Take a full timed 100-question practice exam a week before test day.